N2XH Control Cables Eca Class
N2XH Control Cables Eca Class
Multi-core, single or multi-wire copper conductor power control cables that are halogen-free and fire-safe. Thanks to their low smoke density, non-flame propagating properties and no corrosive gas emissions for protecting life and property in case of fire. This cable type is ideal for general power supply and distribution in indoor applications. Nexans' specially developed easy-stripping feature reduces cable installation time by up to 56%.
Read moreN2XH 7G1.5 mm2
Nexans ref. 10530971 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Conductor flexibility: Stranded class 2
- Number of cores: 7
- Conductor cross-section: 1.5 mm²
- Nominal outer diameter: 13.0 mm
- Approximate weight: 260 kg/km
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 15 A
- Permissible current rating when buried: 14 A
N2XH 7G1.5 mm2
Nexans ref. 10543789 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular solid (RE)
- Conductor flexibility: Solid class 1
- Number of cores: 7
- Conductor cross-section: 1.5 mm²
- Nominal outer diameter: 13.0 mm
- Approximate weight: 240 kg/km
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 15 A
- Permissible current rating when buried: 14 A
N2XH 7G2.5 mm2
Nexans ref. 10530331 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Conductor flexibility: Stranded class 2
- Number of cores: 7
- Conductor cross-section: 2.5 mm²
- Nominal outer diameter: 15.0 mm
- Approximate weight: 340 kg/km
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 21 A
- Permissible current rating when buried: 18 A
N2XH 7G2.5 mm2
Nexans ref. 10543790 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular solid (RE)
- Conductor flexibility: Solid class 1
- Number of cores: 7
- Conductor cross-section: 2.5 mm²
- Nominal outer diameter: 14.0 mm
- Approximate weight: 320 kg/km
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 21 A
- Permissible current rating when buried: 18 A
N2XH 10G1.5 mm2
Nexans ref. 10530972 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Conductor flexibility: Stranded class 2
- Number of cores: 10
- Conductor cross-section: 1.5 mm²
- Nominal outer diameter: 17.0 mm
- Approximate weight: 400 kg/km
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 13 A
- Permissible current rating when buried: 12 A
N2XH 10G1.5 mm2
Nexans ref. 10543757 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular solid (RE)
- Conductor flexibility: Solid class 1
- Number of cores: 10
- Conductor cross-section: 1.5 mm²
- Nominal outer diameter: 17.0 mm
- Approximate weight: 360 kg/km
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 13 A
- Permissible current rating when buried: 12 A
N2XH 10G2.5 mm2
Nexans ref. 10530974 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Conductor flexibility: Stranded class 2
- Number of cores: 10
- Conductor cross-section: 2.5 mm²
- Nominal outer diameter: 19.0 mm
- Approximate weight: 500 kg/km
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 18 A
- Permissible current rating when buried: 15 A
N2XH 10G2.5 mm2
Nexans ref. 10543758 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular solid (RE)
- Conductor flexibility: Solid class 1
- Number of cores: 10
- Conductor cross-section: 2.5 mm²
- Nominal outer diameter: 18.0 mm
- Approximate weight: 480 kg/km
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 18 A
- Permissible current rating when buried: 15 A
N2XH 12G1.5 mm2
Nexans ref. 10530970 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Conductor flexibility: Stranded class 2
- Number of cores: 12
- Conductor cross-section: 1.5 mm²
- Nominal outer diameter: 17.0 mm
- Approximate weight: 380 kg/km
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 12 A
- Permissible current rating when buried: 10 A
N2XH 12G1.5 mm2
Nexans ref. 10543759 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular solid (RE)
- Conductor flexibility: Solid class 1
- Number of cores: 12
- Conductor cross-section: 1.5 mm²
- Nominal outer diameter: 17.0 mm
- Approximate weight: 380 kg/km
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 12 A
- Permissible current rating when buried: 10 A
N2XH 12G2.5 mm2
Nexans ref. 10530332 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Conductor flexibility: Stranded class 2
- Number of cores: 12
- Conductor cross-section: 2.5 mm²
- Nominal outer diameter: 19.0 mm
- Approximate weight: 550 kg/km
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 16 A
- Permissible current rating when buried: 14 A
N2XH 14G1.5 mm2
Nexans ref. 10530975 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Conductor flexibility: Stranded class 2
- Number of cores: 14
- Conductor cross-section: 1.5 mm²
- Nominal outer diameter: 18.0 mm
- Approximate weight: 440 kg/km
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 12 A
- Permissible current rating when buried: 10 A
N2XH 14G1.5 mm2
Nexans ref. 10543771 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular solid (RE)
- Conductor flexibility: Solid class 1
- Number of cores: 14
- Conductor cross-section: 1.5 mm²
- Nominal outer diameter: 17.0 mm
- Approximate weight: 440 kg/km
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 12 A
- Permissible current rating when buried: 10 A
N2XH 14G2.5 mm2
Nexans ref. 10530976 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Conductor flexibility: Stranded class 2
- Number of cores: 14
- Conductor cross-section: 2.5 mm²
- Nominal outer diameter: 19.0 mm
- Approximate weight: 600 kg/km
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 16 A
- Permissible current rating when buried: 14 A
N2XH 14G2.5 mm2
Nexans ref. 10543772 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular solid (RE)
- Conductor flexibility: Solid class 1
- Number of cores: 14
- Conductor cross-section: 2.5 mm²
- Nominal outer diameter: 18.0 mm
- Approximate weight: 550 kg/km
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 16 A
- Permissible current rating when buried: 14 A
N2XH 16G1.5 mm2
Nexans ref. 10530980 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Conductor flexibility: Stranded class 2
- Number of cores: 16
- Conductor cross-section: 1.5 mm²
- Nominal outer diameter: 18.0 mm
- Approximate weight: 480 kg/km
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 10 A
- Permissible current rating when buried: 9 A
N2XH 16G1.5 mm2
Nexans ref. 10543773 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular solid (RE)
- Conductor flexibility: Solid class 1
- Number of cores: 16
- Conductor cross-section: 1.5 mm²
- Nominal outer diameter: 18.0 mm
- Approximate weight: 480 kg/km
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 10 A
- Permissible current rating when buried: 9 A
N2XH 16G2.5 mm2
Nexans ref. 10530981 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Conductor flexibility: Stranded class 2
- Number of cores: 16
- Conductor cross-section: 2.5 mm²
- Nominal outer diameter: 20.0 mm
- Approximate weight: 650 kg/km
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 14 A
- Permissible current rating when buried: 12 A
N2XH 16G2.5 mm2
Nexans ref. 10543774 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular solid (RE)
- Conductor flexibility: Solid class 1
- Number of cores: 16
- Conductor cross-section: 2.5 mm²
- Nominal outer diameter: 19.0 mm
- Approximate weight: 600 kg/km
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 14 A
- Permissible current rating when buried: 12 A
N2XH 19G1.5 mm2
Nexans ref. 10530982 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Conductor flexibility: Stranded class 2
- Number of cores: 19
- Conductor cross-section: 1.5 mm²
- Nominal outer diameter: 19.0 mm
- Approximate weight: 550 kg/km
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 10 A
- Permissible current rating when buried: 9 A
N2XH 19G1.5 mm2
Nexans ref. 10543775 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular solid (RE)
- Conductor flexibility: Solid class 1
- Number of cores: 19
- Conductor cross-section: 1.5 mm²
- Nominal outer diameter: 19.0 mm
- Approximate weight: 550 kg/km
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 10 A
- Permissible current rating when buried: 9 A
N2XH 19G2.5 mm2
Nexans ref. 10530983 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Conductor flexibility: Stranded class 2
- Number of cores: 19
- Conductor cross-section: 2.5 mm²
- Nominal outer diameter: 21.0 mm
- Approximate weight: 750 kg/km
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 14 A
- Permissible current rating when buried: 12 A
N2XH 19G2.5 mm2
Nexans ref. 10543776 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular solid (RE)
- Conductor flexibility: Solid class 1
- Number of cores: 19
- Conductor cross-section: 2.5 mm²
- Nominal outer diameter: 20.0 mm
- Approximate weight: 700 kg/km
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 14 A
- Permissible current rating when buried: 12 A
N2XH 24G1.5 mm2
Nexans ref. 10530987 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular solid (RE)
- Conductor flexibility: Solid class 1
- Number of cores: 24
- Conductor cross-section: 1.5 mm²
- Nominal outer diameter: 23.7 mm
- Approximate weight: 650 kg/km
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 9 A
- Permissible current rating when buried: 7 A
N2XH 24G2.5 mm2
Nexans ref. 10530988 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular solid (RE)
- Conductor flexibility: Solid class 1
- Number of cores: 24
- Conductor cross-section: 2.5 mm²
- Nominal outer diameter: 26.4 mm
- Approximate weight: 900 kg/km
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 13 A
- Permissible current rating when buried: 10 A
Description
Description
Standards
-
ProductIEC 60502-1
Application
N2XH cable is an installation/power cable widely used in applications requiring high levels of fire safety due to the significant number of human lives at stake, such as:
- Industrial and Commercial Electrical Installations
- Electrical panels and control panels
- Indoor applications with fire risk (hotels, schools, high-rise buildings, hospitals, data centers, airports, offices etc.)
- Installations in public places
- Tunnels and underground infrastructures
- Wiring for indoor power and lighting circuits in dry environments
Construction
- Conductor:Copper
- Insulation:XLPE
- Filler:LSZH
- Outer sheath:LSZH
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania