N2XCH FE 180 Screened Fire-Resistant Cables
N2XCH FE 180 Screened Fire-Resistant Cables
Fire-resistant, single or multi-core, single or multi-wire copper conductor power cables with concentric copper screen/conductor, halogen-free and fire-safe. Thanks to their low smoke density, non-flame propagating properties and no corrosive gas emissions for protecting life and property in case of fire. They are ideal for general power supply and distribution in indoor applications. Their concentric copper screen/conductor makes them especially suitable for environments requiring electrical protection. They maintain circuit integrity for 180 minutes during a fire (FE 180).
Read moreN2XCH FE 180 3x1.5/1.5 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (1000m)
- Core identification: Brown, black, grey
- Number of cores: 3
- Conductor cross-section: 1.5 mm²
- Outer Diameter: 13 mm
- Approximate weight: 220 kg/km
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 23 A
- Permissible current rating when buried: 23 A
- Permissible short circuit current screen 1s: .27 kA
N2XCH FE 180 3x2.5/2.5 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (1000m)
- Core identification: Brown, black, grey
- Number of cores: 3
- Conductor cross-section: 2.5 mm²
- Outer Diameter: 14 mm
- Approximate weight: 280 kg/km
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 32 A
- Permissible current rating when buried: 30 A
- Permissible short circuit current screen 1s: .37 kA
N2XCH FE 180 3x4/4 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (1000m)
- Core identification: Brown, black, grey
- Number of cores: 3
- Conductor cross-section: 4 mm²
- Outer Diameter: 15 mm
- Approximate weight: 360 kg/km
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
- Permissible current rating in open air: 42 A
- Permissible current rating when buried: 39 A
- Permissible short circuit current screen 1s: .58 kA
N2XCH FE 180 3x6/6 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (1000m)
- Core identification: Brown, black, grey
- Number of cores: 3
- Conductor cross-section: 6 mm²
- Outer Diameter: 17 mm
- Approximate weight: 460 kg/km
- Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
- Permissible current rating in open air: 54 A
- Permissible current rating when buried: 49 A
- Permissible short circuit current screen 1s: .81 kA
N2XCH FE 180 3x10/10 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (1000m)
- Core identification: Brown, black, grey
- Number of cores: 3
- Conductor cross-section: 10 mm²
- Outer Diameter: 18 mm
- Approximate weight: 650 kg/km
- Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
- Permissible current rating in open air: 75 A
- Permissible current rating when buried: 65 A
- Permissible short circuit current screen 1s: 1.4 kA
N2XCH FE 180 3x16/16 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (1000m)
- Core identification: Brown, black, grey
- Number of cores: 3
- Conductor cross-section: 16 mm²
- Outer Diameter: 20 mm
- Approximate weight: 900 kg/km
- Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
- Permissible current rating in open air: 100 A
- Permissible current rating when buried: 84 A
- Permissible short circuit current screen 1s: 2.17 kA
N2XCH FE 180 3x25/16 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (1000m)
- Core identification: Brown, black, grey
- Number of cores: 3
- Conductor cross-section: 25 mm²
- Outer Diameter: 24 mm
- Approximate weight: 1300 kg/km
- Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
- Permissible current rating in open air: 127 A
- Permissible current rating when buried: 107 A
- Permissible short circuit current screen 1s: 2.17 kA
N2XCH FE 180 3x35/16 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (1000m)
- Core identification: Brown, black, grey
- Number of cores: 3
- Conductor cross-section: 35 mm²
- Outer Diameter: 26 mm
- Approximate weight: 1600 kg/km
- Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
- Permissible current rating in open air: 158 A
- Permissible current rating when buried: 129 A
- Permissible short circuit current screen 1s: 2.17 kA
N2XCH FE 180 3x50/25 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (1000m)
- Core identification: Brown, black, grey
- Number of cores: 3
- Conductor cross-section: 50 mm²
- Outer Diameter: 30 mm
- Approximate weight: 2250 kg/km
- Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
- Permissible current rating in open air: 192 A
- Permissible current rating when buried: 153 A
- Permissible short circuit current screen 1s: 3.3 kA
N2XCH FE 180 3x70/35 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (1000m)
- Core identification: Brown, black, grey
- Number of cores: 3
- Conductor cross-section: 70 mm²
- Outer Diameter: 34 mm
- Approximate weight: 3000 kg/km
- Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
- Permissible current rating in open air: 246 A
- Permissible current rating when buried: 188 A
- Permissible short circuit current screen 1s: 4.46 kA
N2XCH FE 180 4x1.5/1.5 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (1000m)
- Core identification: Blue, brown, black, grey
- Number of cores: 4
- Conductor cross-section: 1.5 mm²
- Outer Diameter: 14 mm
- Approximate weight: 240 kg/km
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 23 A
- Permissible current rating when buried: 23 A
- Permissible short circuit current screen 1s: .27 kA
N2XCH FE 180 4x2.5/2.5 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (1000m)
- Core identification: Blue, brown, black, grey
- Number of cores: 4
- Conductor cross-section: 2.5 mm²
- Outer Diameter: 15 mm
- Approximate weight: 320 kg/km
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 32 A
- Permissible current rating when buried: 30 A
- Permissible short circuit current screen 1s: .37 kA
N2XCH FE 180 4x4/4 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (1000m)
- Core identification: Blue, brown, black, grey
- Number of cores: 4
- Conductor cross-section: 4 mm²
- Outer Diameter: 17 mm
- Approximate weight: 420 kg/km
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
- Permissible current rating in open air: 42 A
- Permissible current rating when buried: 39 A
- Permissible short circuit current screen 1s: .58 kA
N2XCH FE 180 4x6/6 mm2
Nexans ref. 10520943 - Country ref. TR
- Packaging: Drum (1000m)
- Core identification: Blue, brown, black, grey
- Number of cores: 4
- Conductor cross-section: 6 mm²
- Outer Diameter: 18 mm
- Approximate weight: 550 kg/km
- Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
- Permissible current rating in open air: 54 A
- Permissible current rating when buried: 49 A
- Permissible short circuit current screen 1s: .81 kA
N2XCH FE 180 4x10/10 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (1000m)
- Core identification: Blue, brown, black, grey
- Number of cores: 4
- Conductor cross-section: 10 mm²
- Outer Diameter: 20 mm
- Approximate weight: 750 kg/km
- Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
- Permissible current rating in open air: 75 A
- Permissible current rating when buried: 65 A
- Permissible short circuit current screen 1s: 1.4 kA
N2XCH FE 180 4x16/16 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (1000m)
- Core identification: Blue, brown, black, grey
- Number of cores: 4
- Conductor cross-section: 16 mm²
- Outer Diameter: 23 mm
- Approximate weight: 1100 kg/km
- Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
- Permissible current rating in open air: 100 A
- Permissible current rating when buried: 84 A
- Permissible short circuit current screen 1s: 2.17 kA
N2XCH FE 180 4x25/16 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (1000m)
- Core identification: Blue, brown, black, grey
- Number of cores: 4
- Conductor cross-section: 25 mm²
- Outer Diameter: 26 mm
- Approximate weight: 1500 kg/km
- Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
- Permissible current rating in open air: 127 A
- Permissible current rating when buried: 107 A
- Permissible short circuit current screen 1s: 2.17 kA
N2XCH FE 180 4x35/16 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (1000m)
- Core identification: Blue, brown, black, grey
- Number of cores: 4
- Conductor cross-section: 35 mm²
- Outer Diameter: 29 mm
- Approximate weight: 1900 kg/km
- Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
- Permissible current rating in open air: 158 A
- Permissible current rating when buried: 129 A
- Permissible short circuit current screen 1s: 2.17 kA
N2XCH FE 180 4x50/25 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (1000m)
- Core identification: Blue, brown, black, grey
- Number of cores: 4
- Conductor cross-section: 50 mm²
- Outer Diameter: 33 mm
- Approximate weight: 2750 kg/km
- Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
- Permissible current rating in open air: 192 A
- Permissible current rating when buried: 153 A
- Permissible short circuit current screen 1s: 3.94 kA
N2XCH FE 180 4x70/35 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (1000m)
- Core identification: Blue, brown, black, grey
- Number of cores: 4
- Conductor cross-section: 70 mm²
- Outer Diameter: 38 mm
- Approximate weight: 3750 kg/km
- Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
- Permissible current rating in open air: 246 A
- Permissible current rating when buried: 188 A
- Permissible short circuit current screen 1s: 4.53 kA
Description
Description
Standards
-
ProductIEC 60502-1
Application
- Indoor applications where fire safety is a priority (hotels, schools, high-rise buildings, hospitals, data centers, airports, offices etc.)
- Systems that require 180 minutes of circuit integrity during fire conditions:
- Warning Systems (fire alarms, smoke detection/alarm devices)
- Smoke Ventilation Systems (tunnel fans)
- Emergency Exits (emergency lighting fixtures)
- Fire Intervention Systems (water pumps, automatic doors)
- Uninterruptible Energy Systems (escalators, elevators in subways)
Construction
- Conductor:copper
- Fire Barrier:mica tape
- Insulation:XLPE
- Filler:LSZH
- Concentric screen:Copper wire + copper tape
- Outher sheath:LSZH
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics