AL/XLPE/WBT/CWS/WBT/FL/LSZH 12/20 kV Cca Class

Products

AL/XLPE/WBT/CWS/WBT/FL/LSZH 1X185/35 mm2

Nexans ref. 10588565 - Country ref. TR

  • Packaging: Drum
  • Conductor cross-section: 185 mm²
  • Approximate weight: 1710 kg/km
  • Maximum outer diameter: 38.3 mm
  • Minimum outer diameter: 34.5 mm
  • Minimum outer sheath thickness: 1.48 mm
  • Max. DC resistance of the conductor at 20°C: 0.164 Ohm/km
  • Impedance at 50 Hz : 0.23 Ohm
  • Perm. current rating buried 20°C - trefoil formation: 317 A
  • Perm. current rating in air 30°C - flat formation: 504 A
  • Reactance at 50 Hz: 0.11 Ohm/km
  • Short Circuit Current 1 s Max : 17.4 kA
  • Voltage Drop: 0.4 V/A.km

 

AL/XLPE/WBT/CWS/WBT/FL/LSZH 1X630/35 mm2

Nexans ref. 10588564 - Country ref. TR

  • Packaging: Drum
  • Conductor cross-section: 630 mm²
  • Approximate weight: 3500 kg/km
  • Maximum outer diameter: 54.5 mm
  • Minimum outer diameter: 49.3 mm
  • Minimum outer sheath thickness: 1.8 mm
  • Max. DC resistance of the conductor at 20°C: 0.0469 Ohm/km
  • Impedance at 50 Hz : 0.1 Ohm
  • Perm. current rating buried 20°C - trefoil formation: 600 A
  • Perm. current rating in air 30°C - flat formation: 930 A
  • Reactance at 50 Hz: 0.09 Ohm/km
  • Short Circuit Current 1 s Max : 59.2 kA
  • Voltage Drop: 0.2 V/A.km

 

Description

Description

Standards

  • Product
    EN 50575; IEC 60228; IEC 60502
  • Test
    IEC 60332-3-24; IEC 60754-1; IEC 60754-2

Application

These are cables with low dielectric losses used in energy networks with sudden load changes where mechanical stresses expected. Laid in residential or industrial areas, underground or in ducts.

Construction

  1. Conductor:Aluminium
  2. Conductor screen:Extruded semi-conductor
  3. Insulation:XLPE
  4. Insulation screen:Extruded semi-conductor (Strippable)
  5. Semi-conducting tape:Water swelling tape
  6. Metallic screen:Copper wires+counter helix tape
  7. Taping: Water swelling tape on the metallic screen
  8. Radial water blocking: Longitudinal aluminium foil sticking to Protective Sheath
  9. Outer sheath:LSZH

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Halogen free
IEC 60754-1

Dimensional characteristics

Dimensional characteristics

Nominal insulation thickness
5.5 mm

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
12 / 20 (24) kV

Usage characteristics

Usage characteristics

Operating temperature, range
-20 ... 60 °C
Flame retardant
IEC 60332-3 Cat. C
Bending factor when laying
12 (xD)
Gases corrosivity
IEC 60754-1; IEC 60754-2
Longitudinal water tightness
Yes
Radial water tightness
Yes
Smoke density
IEC 61034-2
U.V resistance
Yes

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close