NA2XH Single Core Cables B2ca Class
NA2XH Single Core Cables B2ca Class
0.6/1 kV XLPE insulated single core, halogen free, flame retardant cable with aluminium conductors
Read moreNA2XH 1x120 mm2
Nexans ref. 10594127 - Country ref. TR
- Packaging: Drum (1000m)
- Sheath colour: Black
- Conductor cross-section: - mm²
- Nominal outer diameter: 17.7 mm
- Approximate weight: 470 kg/km
- Max. DC resistance of the conductor at 20°C: 0.253 Ohm/km
- Perm. current rating in air 30°C - flat formation: 387 A
- Perm. current rating in air 30°C - trefoil formation: 296 A
- Permissible current rating buried/direct 20°C: 197 A
NA2XH 1x50 mm2
Nexans ref. 10581878 - Country ref. TR
- Packaging: Drum (1000m)
- Sheath colour: Green
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 12.2 mm
- Approximate weight: 230 kg/km
- Max. DC resistance of the conductor at 20°C: 0.641 Ohm/km
- Perm. current rating in air 30°C - flat formation: 210 A
- Perm. current rating in air 30°C - trefoil formation: 159 A
- Permissible current rating buried/direct 20°C: 117 A
NA2XH 1x50 mm2
Nexans ref. 10594124 - Country ref. TR
- Packaging: Drum (1000m)
- Sheath colour: Black
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 12.6 mm
- Approximate weight: 220 kg/km
- Max. DC resistance of the conductor at 20°C: 0.641 Ohm/km
- Perm. current rating in air 30°C - flat formation: 210 A
- Perm. current rating in air 30°C - trefoil formation: 159 A
- Permissible current rating buried/direct 20°C: 117 A
NA2XH 1x70 mm2
Nexans ref. 10594125 - Country ref. TR
- Packaging: Drum (1000m)
- Sheath colour: Black
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 14.8 mm
- Approximate weight: 300 kg/km
- Max. DC resistance of the conductor at 20°C: 0.443 Ohm/km
- Perm. current rating in air 30°C - flat formation: 271 A
- Perm. current rating in air 30°C - trefoil formation: 206 A
- Permissible current rating buried/direct 20°C: 144 A
NA2XH 1x95 mm2
Nexans ref. 10571345 - Country ref. TR
- Packaging: Drum (1000m)
- Sheath colour: Black
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 16.0 mm
- Approximate weight: 390 kg/km
- Max. DC resistance of the conductor at 20°C: 0.32 Ohm/km
- Perm. current rating in air 30°C - flat formation: 332 A
- Perm. current rating in air 30°C - trefoil formation: 253 A
- Permissible current rating buried/direct 20°C: 172 A
NA2XH 1x95 mm2
Nexans ref. 10594126 - Country ref. TR
- Packaging: Drum (1000m)
- Sheath colour: Black
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 16.4 mm
- Approximate weight: 400 kg/km
- Max. DC resistance of the conductor at 20°C: 0.32 Ohm/km
- Perm. current rating in air 30°C - flat formation: 332 A
- Perm. current rating in air 30°C - trefoil formation: 253 A
- Permissible current rating buried/direct 20°C: 172 A
NA2XH 1x120 mm2
Nexans ref. 10581877 - Country ref. TR
- Packaging: Drum (1000m)
- Sheath colour: Green
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 17.4 mm
- Approximate weight: 480 kg/km
- Max. DC resistance of the conductor at 20°C: 0.253 Ohm/km
- Perm. current rating in air 30°C - flat formation: 387 A
- Perm. current rating in air 30°C - trefoil formation: 296 A
- Permissible current rating buried/direct 20°C: 197 A
NA2XH 1x150 mm2
Nexans ref. 10571344 - Country ref. TR
- Packaging: Drum (1000m)
- Sheath colour: Black
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 20.0 mm
- Approximate weight: 590 kg/km
- Max. DC resistance of the conductor at 20°C: 0.206 Ohm/km
- Perm. current rating in air 30°C - flat formation: 448 A
- Perm. current rating in air 30°C - trefoil formation: 343 A
- Permissible current rating buried/direct 20°C: 220 A
NA2XH 1x150 mm2
Nexans ref. 10594128 - Country ref. TR
- Packaging: Drum (1000m)
- Sheath colour: Black
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 19.8 mm
- Approximate weight: 570 kg/km
- Max. DC resistance of the conductor at 20°C: 0.206 Ohm/km
- Perm. current rating in air 30°C - flat formation: 448 A
- Perm. current rating in air 30°C - trefoil formation: 343 A
- Permissible current rating buried/direct 20°C: 220 A
NA2XH 1x185 mm2
Nexans ref. 10571343 - Country ref. TR
- Packaging: Drum (1000m)
- Sheath colour: Black
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 22.0 mm
- Approximate weight: 720 kg/km
- Max. DC resistance of the conductor at 20°C: 0.164 Ohm/km
- Perm. current rating in air 30°C - flat formation: 515 A
- Perm. current rating in air 30°C - trefoil formation: 395 A
- Permissible current rating buried/direct 20°C: 250 A
NA2XH 1x185 mm2
Nexans ref. 10594129 - Country ref. TR
- Packaging: Drum (1000m)
- Sheath colour: Black
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 21.8 mm
- Approximate weight: 710 kg/km
- Max. DC resistance of the conductor at 20°C: 0.164 Ohm/km
- Perm. current rating in air 30°C - flat formation: 515 A
- Perm. current rating in air 30°C - trefoil formation: 395 A
- Permissible current rating buried/direct 20°C: 250 A
NA2XH 1x240 mm2
Nexans ref. 10571342 - Country ref. TR
- Packaging: Drum (1000m)
- Sheath colour: Black
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 25.0 mm
- Approximate weight: 910 kg/km
- Max. DC resistance of the conductor at 20°C: 0.125 Ohm/km
- Perm. current rating in air 30°C - flat formation: 611 A
- Perm. current rating in air 30°C - trefoil formation: 471 A
- Permissible current rating buried/direct 20°C: 290 A
NA2XH 1x240 mm2
Nexans ref. 10594140 - Country ref. TR
- Packaging: Drum (1000m)
- Sheath colour: Black
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 24.6 mm
- Approximate weight: 890 kg/km
- Max. DC resistance of the conductor at 20°C: 0.125 Ohm/km
- Perm. current rating in air 30°C - flat formation: 611 A
- Perm. current rating in air 30°C - trefoil formation: 471 A
- Permissible current rating buried/direct 20°C: 290 A
NA2XH 1x300 mm2
Nexans ref. 10594141 - Country ref. TR
- Packaging: Drum (1000m)
- Sheath colour: Black
- Conductor cross-section: 300 mm²
- Nominal outer diameter: 27.3 mm
- Approximate weight: 1110 kg/km
- Max. DC resistance of the conductor at 20°C: 0.1 Ohm/km
- Perm. current rating in air 30°C - flat formation: 708 A
- Perm. current rating in air 30°C - trefoil formation: 547 A
- Permissible current rating buried/direct 20°C: 326 A
Description
Description
Standards
-
ProductIEC 60502-1
Application
Used in energy networks in hotels, schools, tunnels, high constructions, hospitals, power plants, data processing centers, business centers where there is a risk of fire
Construction
- Conductor:Aluminium
- Insulation:XLPE
- Outer sheath:LSZH
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania