N2XCH FE 180 Screened Fire-Resistant Cables

Products

N2XCH FE 180 3x1.5/1.5 mm2

Nexans ref. - Country ref. TR

  • Packaging: Drum (1000m)
  • Core identification: Brown, black, grey
  • Number of cores: 3
  • Conductor cross-section: 1.5 mm²
  • Outer Diameter: 13 mm
  • Approximate weight: 220 kg/km
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 23 A
  • Permissible current rating when buried: 23 A
  • Permissible short circuit current screen 1s: .27 kA

 

N2XCH FE 180 3x2.5/2.5 mm2

Nexans ref. - Country ref. TR

  • Packaging: Drum (1000m)
  • Core identification: Brown, black, grey
  • Number of cores: 3
  • Conductor cross-section: 2.5 mm²
  • Outer Diameter: 14 mm
  • Approximate weight: 280 kg/km
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 32 A
  • Permissible current rating when buried: 30 A
  • Permissible short circuit current screen 1s: .37 kA

 

N2XCH FE 180 3x4/4 mm2

Nexans ref. - Country ref. TR

  • Packaging: Drum (1000m)
  • Core identification: Brown, black, grey
  • Number of cores: 3
  • Conductor cross-section: 4 mm²
  • Outer Diameter: 15 mm
  • Approximate weight: 360 kg/km
  • Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
  • Permissible current rating in open air: 42 A
  • Permissible current rating when buried: 39 A
  • Permissible short circuit current screen 1s: .58 kA

 

N2XCH FE 180 3x6/6 mm2

Nexans ref. - Country ref. TR

  • Packaging: Drum (1000m)
  • Core identification: Brown, black, grey
  • Number of cores: 3
  • Conductor cross-section: 6 mm²
  • Outer Diameter: 17 mm
  • Approximate weight: 460 kg/km
  • Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
  • Permissible current rating in open air: 54 A
  • Permissible current rating when buried: 49 A
  • Permissible short circuit current screen 1s: .81 kA

 

N2XCH FE 180 3x10/10 mm2

Nexans ref. - Country ref. TR

  • Packaging: Drum (1000m)
  • Core identification: Brown, black, grey
  • Number of cores: 3
  • Conductor cross-section: 10 mm²
  • Outer Diameter: 18 mm
  • Approximate weight: 650 kg/km
  • Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
  • Permissible current rating in open air: 75 A
  • Permissible current rating when buried: 65 A
  • Permissible short circuit current screen 1s: 1.4 kA

 

N2XCH FE 180 3x16/16 mm2

Nexans ref. - Country ref. TR

  • Packaging: Drum (1000m)
  • Core identification: Brown, black, grey
  • Number of cores: 3
  • Conductor cross-section: 16 mm²
  • Outer Diameter: 20 mm
  • Approximate weight: 900 kg/km
  • Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
  • Permissible current rating in open air: 100 A
  • Permissible current rating when buried: 84 A
  • Permissible short circuit current screen 1s: 2.17 kA

 

N2XCH FE 180 3x25/16 mm2

Nexans ref. - Country ref. TR

  • Packaging: Drum (1000m)
  • Core identification: Brown, black, grey
  • Number of cores: 3
  • Conductor cross-section: 25 mm²
  • Outer Diameter: 24 mm
  • Approximate weight: 1300 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
  • Permissible current rating in open air: 127 A
  • Permissible current rating when buried: 107 A
  • Permissible short circuit current screen 1s: 2.17 kA

 

N2XCH FE 180 3x35/16 mm2

Nexans ref. - Country ref. TR

  • Packaging: Drum (1000m)
  • Core identification: Brown, black, grey
  • Number of cores: 3
  • Conductor cross-section: 35 mm²
  • Outer Diameter: 26 mm
  • Approximate weight: 1600 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
  • Permissible current rating in open air: 158 A
  • Permissible current rating when buried: 129 A
  • Permissible short circuit current screen 1s: 2.17 kA

 

N2XCH FE 180 3x50/25 mm2

Nexans ref. - Country ref. TR

  • Packaging: Drum (1000m)
  • Core identification: Brown, black, grey
  • Number of cores: 3
  • Conductor cross-section: 50 mm²
  • Outer Diameter: 30 mm
  • Approximate weight: 2250 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
  • Permissible current rating in open air: 192 A
  • Permissible current rating when buried: 153 A
  • Permissible short circuit current screen 1s: 3.3 kA

 

N2XCH FE 180 3x70/35 mm2

Nexans ref. - Country ref. TR

  • Packaging: Drum (1000m)
  • Core identification: Brown, black, grey
  • Number of cores: 3
  • Conductor cross-section: 70 mm²
  • Outer Diameter: 34 mm
  • Approximate weight: 3000 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
  • Permissible current rating in open air: 246 A
  • Permissible current rating when buried: 188 A
  • Permissible short circuit current screen 1s: 4.46 kA

 

N2XCH FE 180 4x1.5/1.5 mm2

Nexans ref. - Country ref. TR

  • Packaging: Drum (1000m)
  • Core identification: Blue, brown, black, grey
  • Number of cores: 4
  • Conductor cross-section: 1.5 mm²
  • Outer Diameter: 14 mm
  • Approximate weight: 240 kg/km
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 23 A
  • Permissible current rating when buried: 23 A
  • Permissible short circuit current screen 1s: .27 kA

 

N2XCH FE 180 4x2.5/2.5 mm2

Nexans ref. - Country ref. TR

  • Packaging: Drum (1000m)
  • Core identification: Blue, brown, black, grey
  • Number of cores: 4
  • Conductor cross-section: 2.5 mm²
  • Outer Diameter: 15 mm
  • Approximate weight: 320 kg/km
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 32 A
  • Permissible current rating when buried: 30 A
  • Permissible short circuit current screen 1s: .37 kA

 

N2XCH FE 180 4x4/4 mm2

Nexans ref. - Country ref. TR

  • Packaging: Drum (1000m)
  • Core identification: Blue, brown, black, grey
  • Number of cores: 4
  • Conductor cross-section: 4 mm²
  • Outer Diameter: 17 mm
  • Approximate weight: 420 kg/km
  • Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
  • Permissible current rating in open air: 42 A
  • Permissible current rating when buried: 39 A
  • Permissible short circuit current screen 1s: .58 kA

 

N2XCH FE 180 4x6/6 mm2

Nexans ref. 10520943 - Country ref. TR

  • Packaging: Drum (1000m)
  • Core identification: Blue, brown, black, grey
  • Number of cores: 4
  • Conductor cross-section: 6 mm²
  • Outer Diameter: 18 mm
  • Approximate weight: 550 kg/km
  • Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
  • Permissible current rating in open air: 54 A
  • Permissible current rating when buried: 49 A
  • Permissible short circuit current screen 1s: .81 kA

 

N2XCH FE 180 4x10/10 mm2

Nexans ref. - Country ref. TR

  • Packaging: Drum (1000m)
  • Core identification: Blue, brown, black, grey
  • Number of cores: 4
  • Conductor cross-section: 10 mm²
  • Outer Diameter: 20 mm
  • Approximate weight: 750 kg/km
  • Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
  • Permissible current rating in open air: 75 A
  • Permissible current rating when buried: 65 A
  • Permissible short circuit current screen 1s: 1.4 kA

 

N2XCH FE 180 4x16/16 mm2

Nexans ref. - Country ref. TR

  • Packaging: Drum (1000m)
  • Core identification: Blue, brown, black, grey
  • Number of cores: 4
  • Conductor cross-section: 16 mm²
  • Outer Diameter: 23 mm
  • Approximate weight: 1100 kg/km
  • Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
  • Permissible current rating in open air: 100 A
  • Permissible current rating when buried: 84 A
  • Permissible short circuit current screen 1s: 2.17 kA

 

N2XCH FE 180 4x25/16 mm2

Nexans ref. - Country ref. TR

  • Packaging: Drum (1000m)
  • Core identification: Blue, brown, black, grey
  • Number of cores: 4
  • Conductor cross-section: 25 mm²
  • Outer Diameter: 26 mm
  • Approximate weight: 1500 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
  • Permissible current rating in open air: 127 A
  • Permissible current rating when buried: 107 A
  • Permissible short circuit current screen 1s: 2.17 kA

 

N2XCH FE 180 4x35/16 mm2

Nexans ref. - Country ref. TR

  • Packaging: Drum (1000m)
  • Core identification: Blue, brown, black, grey
  • Number of cores: 4
  • Conductor cross-section: 35 mm²
  • Outer Diameter: 29 mm
  • Approximate weight: 1900 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
  • Permissible current rating in open air: 158 A
  • Permissible current rating when buried: 129 A
  • Permissible short circuit current screen 1s: 2.17 kA

 

N2XCH FE 180 4x50/25 mm2

Nexans ref. - Country ref. TR

  • Packaging: Drum (1000m)
  • Core identification: Blue, brown, black, grey
  • Number of cores: 4
  • Conductor cross-section: 50 mm²
  • Outer Diameter: 33 mm
  • Approximate weight: 2750 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
  • Permissible current rating in open air: 192 A
  • Permissible current rating when buried: 153 A
  • Permissible short circuit current screen 1s: 3.94 kA

 

N2XCH FE 180 4x70/35 mm2

Nexans ref. - Country ref. TR

  • Packaging: Drum (1000m)
  • Core identification: Blue, brown, black, grey
  • Number of cores: 4
  • Conductor cross-section: 70 mm²
  • Outer Diameter: 38 mm
  • Approximate weight: 3750 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
  • Permissible current rating in open air: 246 A
  • Permissible current rating when buried: 188 A
  • Permissible short circuit current screen 1s: 4.53 kA

 

Description

Description

Standards

  • International
    IEC 60502-1

Application:

Used in energy networks in hotels, schools, tunnels, high constructions, hospitals, power plants, data processing centers, business centers where there is a risk of fire.Incase of mechanical damage the screen prevents any damage due to power leak to the surrounding.

 

Construction:

  1. Conductor:copper
  2. Fire Barrier:mica tape
  3. Insulation:XLPE
  4. Filler:LSZH
  5. Concentric screen:Copper wire + copper tape
  6. Outher sheath:LSZH

 

Marking:

NEXANS  IEC 60502  N2XCH  FE 180 Number of cores x cross section 0.6/1 kV ''YEAR''

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor shape
Circular stranded (RM)
Conductor flexibility
-
Conductor material
Copper
Halogen free
Yes
Insulation
XLPE (Cross-linked Polyethylene)
Outer sheath
LSZH
Screen
Copper wires + copper tape
Sheath colour
Black

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0,6/1 kV

Usage characteristics

Usage characteristics

Smoke density
IEC 61034
Bending factor when laying
8 (xD)
Fire resistant
IEC 60331-21
Flame retardant
IEC 60332-3 Cat. C
Gases corrosivity
IEC 60754-2
Max. conductor temperature in service
90 °C
Operating temperature, range
-20 ... 60 °C
Short-circuit max. conductor temperature
250 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close